OVERVIEW.
APC Back-UPS 950VA, 230V, AVR, IEC Sockets
Battery Backup & Surge Protector for Electronics and Computers
- Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
- Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
- Telephone dataline surge protection
Provides protection of connected equipment from power surges traveling on telephone lines.
- USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
LED status display
Quickly understand unit and power status with visual indicators.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Protection
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Technical Specifications
Max Configurable Power (Watts):480Watts / 950VA
Output Frequency (sync to mains):50/60 Hz +/-1 Hz
Output Frequency (not synced):50/60 Hz +/-1 Hz
Topology:Line Interactive
Waveform type:Stepped approximation to a sinewave
Input frequency:50/60 Hz +/- 3 Hz (auto sensing)
Input voltage range for main operations:150 – 280 V
Number of Power Cords:1
Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Included Battery Modules:1
Typical recharge time:8hour(s)
Expected Battery Life (years):2 – 5
Battery Volt-Amp-Hour Capacity:76